ClinVar Miner

Submissions for variant NM_000540.3(RYR1):c.15015G>A (p.Thr5005=)

gnomAD frequency: 0.00009  dbSNP: rs2229149
Minimum review status: Collection method:
Minimum conflict level:
ClinVar version:
Total submissions: 9
Download table as spreadsheet
Submitter RCV SCV Clinical significance Condition Last evaluated Review status Method Comment
PreventionGenetics, part of Exact Sciences RCV000241903 SCV000304855 likely benign not specified criteria provided, single submitter clinical testing
Illumina Laboratory Services, Illumina RCV000308165 SCV000413048 likely benign Central core myopathy 2016-06-14 criteria provided, single submitter clinical testing
Illumina Laboratory Services, Illumina RCV000362889 SCV000413049 likely benign Neuromuscular disease, congenital, with uniform type 1 fiber 2016-06-14 criteria provided, single submitter clinical testing
Illumina Laboratory Services, Illumina RCV000277489 SCV000413050 likely benign Malignant hyperthermia, susceptibility to, 1 2018-01-12 criteria provided, single submitter clinical testing This variant was observed in the ICSL laboratory as part of a predisposition screen in an ostensibly healthy population. It had not been previously curated by ICSL or reported in the Human Gene Mutation Database (HGMD: prior to June 1st, 2018), and was therefore a candidate for classification through an automated scoring system. Utilizing variant allele frequency, disease prevalence and penetrance estimates, and inheritance mode, an automated score was calculated to assess if this variant is too frequent to cause the disease. Based on the score and internal cut-off values, a variant classified as likely benign is not then subjected to further curation. The score for this variant resulted in a classification of likely benign for this disease.
Illumina Laboratory Services, Illumina RCV000332546 SCV000413051 uncertain significance Congenital multicore myopathy with external ophthalmoplegia 2018-01-12 criteria provided, single submitter clinical testing This variant was observed in the ICSL laboratory as part of a predisposition screen in an ostensibly healthy population. It had not been previously curated by ICSL or reported in the Human Gene Mutation Database (HGMD: prior to June 1st, 2018), and was therefore a candidate for classification through an automated scoring system. Utilizing variant allele frequency, disease prevalence and penetrance estimates, and inheritance mode, an automated score was calculated to assess if this variant is too frequent to cause the disease. Based on the score, this variant could not be ruled out of causing disease and therefore its association with disease required further investigation. A literature search was performed for the gene, cDNA change, and amino acid change (if applicable). No publications were found based on this search. This variant was therefore classified as a variant of unknown significance for this disease.
Labcorp Genetics (formerly Invitae), Labcorp RCV001080361 SCV000777644 benign RYR1-related disorder 2024-01-18 criteria provided, single submitter clinical testing
Baylor Genetics RCV000308165 SCV001527386 uncertain significance Central core myopathy 2018-02-19 criteria provided, single submitter clinical testing This variant was determined to be of uncertain significance according to ACMG Guidelines, 2015 [PMID:25741868].
All of Us Research Program, National Institutes of Health RCV000277489 SCV004816290 likely benign Malignant hyperthermia, susceptibility to, 1 2023-12-14 criteria provided, single submitter clinical testing
GeneDx RCV004721322 SCV005327273 uncertain significance not provided 2023-06-08 criteria provided, single submitter clinical testing Has not been previously published as pathogenic or benign to our knowledge; In silico analysis suggests this variant may impact gene splicing. In the absence of RNA/functional studies, the actual effect of this sequence change is unknown.

The information on this website is not intended for direct diagnostic use or medical decision-making without review by a genetics professional. Individuals should not change their health behavior solely on the basis of information contained on this website. Neither the University of Utah nor the National Institutes of Health independently verfies the submitted information. If you have questions about the information contained on this website, please see a health care professional.